Black Friday: 60% off yearly plans with code BF2026, until November 30. See the deal

Glossary

Synthetic monitoring: scripted checks from outside

Synthetic monitoring means running scheduled, automated requests against your site or API from outside your infrastructure to test availability and behavior as a user would see it. It is a form of black-box monitoring that alerts when a check fails.

The short answer
  • Probes request your URL on a schedule, from one or more locations.
  • A check passes only if status, content and certificate all pass.
  • Several locations separate a real outage from a local network problem.

What does a synthetic check test?

Pass criteria of Google Cloud uptime checks, one real implementation
CriterionDefault behavior
ProtocolsHTTP, HTTPS and TCP
HTTP statusAny 2xx response passes by default
Content matchRequired text must be present, if configured
RedirectsFollowed. The final response is evaluated
TLS certificateFor HTTPS the certificate must be valid. Expired or self-signed certificates fail
Failure ruleFails when more than one location gets no response within the timeout

Per Google Cloud: Uptime checks. Other vendors differ.

How does it compare with other monitoring?

Black-box (synthetic)

Tests externally visible behavior as a user would see it. Symptom-oriented, so it suits paging, but it only fires once users are affected.

White-box

Uses internals such as logs and metrics. Reveals imminent problems and is essential for debugging.

Heartbeat

Waits for your job to report in and alerts on silence. Covers scheduled work with nothing to probe.

Common questions

What is the difference between synthetic monitoring and real user monitoring?

Synthetic monitoring generates its own traffic on a schedule, so it works at 3 a.m. with no visitors and gives consistent measurements. Real user monitoring records what actual visitors experience. Synthetic checks detect outages fast. Real user data shows variety across devices and networks.

How often should synthetic checks run?

More often detects outages sooner but costs more. Tools differ: Google Cloud documents frequency as a setting with examples at 5 minutes, and monitoring services commonly offer intervals from 1 to 10 minutes or more. Pick the shortest interval that fits your alert policy.

Why check from multiple locations?

A single probe cannot tell a site outage from a problem on the path between that probe and the site. Requiring failures from more than one location, as Google Cloud does, cuts false alarms and also reveals region-specific outages.

Monitor your site from outside

Aepto checks uptime from 1 to 6 regions, depending on plan, and alerts through one Attention queue.